Philip Ralph t/a Boilerserv, 5, Marlpit Cottages, Heath Road, Boughton Monchelsea, Maidstone, Kent. ME17 4JN.  Landline 01622 744040 or 01580 230328.   Mobile 07774 432465.    email:     philip@boilerserv.co.uk.

01622 744040

cardpaymentlogos

Boilerserv

accepts

6 Year Workmanship Warranty on all Installations.

OhEIMcx_skAgxawesE_hgoebRqM
uXeRyiB2FgfpxQ0tykTpQnC44jY

Check the photocell. Unplug it, Pull it out, note it faces in the same direction as the blast tube, it needs to go back in facing the same direction or it won't see the flame and it won't come out unless the burner is out. Clean the glass bulb on its tip with a damp paper towel.

20170918_144606
20170918_144611
20170918_144626
20170918_144635
20170918_145407

Picture on left shows  a clean photocell.

Put the burner back in and check that the center of the airflap adjuster is inline with the Allen head on the bottom corner as in the picture on the right.

Connect oil.

Connect thermostat.

Connect the mains electrics last.