Philip Ralph t/a Boilerserv, 5, Marlpit Cottages, Heath Road, Boughton Monchelsea, Maidstone, Kent. ME17 4JN. Landline 01622 744040 or 01580 230328. Mobile 07774 432465. email: philip@boilerserv.co.uk.
01622 744040

Boilerserv
accepts
6 Year Workmanship Warranty on all Installations.


A Danfoss 0.30 x 60H spec nozzle is the only nozzle to use in these burners. Do not touch the firing end of the nozzle as you may contaminate it. Pinch the nozzle up with the 2 spanners.






Put the blast tube back on so that the drip hole will face down when the burner is back in position, there are 2 drip holes, one will face downwards. Turn the burner over and unclip the timer (green or orange) and lay it to the left to allow the fan motor assembly removal. Use a 2.5mm Allen key to remove the 3 Allen head machine screws that are at roughly 10, 1 and 6 o'clock on the fan housing.