top of page
HCPckqtd0Jq26hEikmq4WSCPa9g
ZccKdSM78BhY6DvjiuR99CgwHsw
LIgeDB7q0kidDTq7u8wvmJS9X7s
boilerserv003
u1b7Exss7w47RY6D0PvTstt0Ob4

Philip Ralph t/a Boilerserv, 5, Marlpit Cottages, Heath Road, Boughton Monchelsea, Maidstone, Kent. ME17 4JN.  Landline 01622 744040 or 01580 230328.   Mobile 07774 432465.    email:     philip@boilerserv.co.uk.

01622 744040

cardpaymentlogos

Boilerserv

accepts

6 Year Workmanship Warranty on all Installations.

OhEIMcx_skAgxawesE_hgoebRqM
uXeRyiB2FgfpxQ0tykTpQnC44jY

A Danfoss 0.30 x 60H spec nozzle is the only nozzle to use in these burners. Do not touch the firing end of the nozzle as you may contaminate it. Pinch the nozzle up with the 2 spanners.

20170918_143200
20170918_143211
20170918_143235
20170918_143356
20170918_143504
20170918_143523

Put the blast tube back on so that the drip hole will face down when the burner is back in position, there are 2 drip holes, one will face downwards. Turn the burner over and unclip the timer (green or orange) and lay it to the left to allow the fan motor assembly removal. Use a 2.5mm Allen key to remove the 3 Allen head machine screws that are  at roughly 10, 1 and 6 o'clock on the fan housing.